Interpreting 10-2 visual field
WebHumphrey field analyser ( HFA) is a tool for measuring the human visual field that is commonly used by optometrists, orthoptists and ophthalmologists, particularly for detecting monocular visual field. [1] … WebAqueous flare, visual field (by an Humphrey Field Analyzer, the central 10-2 SITA-Standard program), and optical coherence tomography measurements were obtained for all patients.
Interpreting 10-2 visual field
Did you know?
WebFeb 22, 2024 · National Center for Biotechnology Information WebApr 15, 2015 · 1. Pick the right test. Most visual field testing is “standard automated perimetry” (SAP). SAP is a computerized, threshold static perimetry that tests the central visual field with a white stimulus on a …
WebHumphrey® Field Analyzer II-i Single Field Analysis A Guide to Interpretation SAMPLE CASE 1: 39-year-old patient with normal visual fi eld. SAMPLE CASE 2: 78-year-old patient with probable glaucomatous fi eld, showing indications of a cataract, and an arcuate scotoma. THRESHOLD VALUES GRAYSCALE MAP PROBABILITY SYMBOLS WebAutomated perimetry is now the current gold standard for both diagnosis and follow-up of glaucoma. The Humphreys visual field analyzer by Zeiss technology is the most widely used machine for visual field assessment. In this write-up, we will illustrate ten pearls to interpret a Humphrey’s Automated visual field printout. 1.
WebAims: To clarify the anatomical relation between the optic disc and temporal raphe and to examine how these are related to test points in the 10-2 visual field test pattern. … WebPurpose: To compare the performance of the pattern standard deviation (PSD) values derived from the central 12 locations of the 24-2 visual field test (C24-2) to the entire 10 …
WebFeb 15, 2024 · The 10-2 has been shown to identify central visual field defects in patients whose 24-2 test would otherwise be considered normal. 11-13 This has prompted some to recommend adding the 10-2 VF to the glaucoma diagnostic protocol. However, another study showed that the large majority of patients with defects on the 10-2 demonstrated …
Advancing technology has revolutionized our toolbox for detecting and following glaucoma progressionbut knowing which tests provide the best diagnostic information is trickier than ever. Although 24-2 and 30-2 perimetry remain the gold standarddespite advancements in retinal nerve fiber layer (RNFL) … See more These glaucoma casesincorporating 10-2 and 24-2 perimetry, RNFL and GCA OCT and optic nerve head photoshighlight the benefits of 10-2 … See more By comparison, 10-2 threshold VF testing assesses 68 points, more than five times as many points in the central 10 degrees compared with 24-2 … See more Key point: Armed with such evidence, one group of researchers recommends 10-2 VF testing always be considered if: there are any depressed points in the central 12 degrees less than 0.5% on 24-2 or 30-2 VF testing; the … See more Although central and paracentral glaucomatous VF damage more commonly occurs in advanced stages of glaucoma, such defects also occur in patients with earlier stages of glaucoma and with relatively … See more dr smith boston children\\u0027s hospitalWebThis 10-2 visual field (VF) was done with the III, red stimulus using the FASTPAC protocol. The field is normal, and illustrates several points to consider in interpreting such VFs. … dr smith boazWebObjective: To determine whether the 24-2 Humphrey visual field (HVF) (Humphrey, San Leandro, CA) strategy provides information comparable to that provided by the 30-2 strategy in patients with optic nerve disease. Methods: In part A of the study, an occluder device was designed to cover the additional outer 22 points tested in the 30-2 strategy of 187 HVFs … coloring pages momo